{"product_id":"max197bcwi","title":"MAX197BCWI+","description":"\u003ch2\u003eMAX197BCWI+ Data Acquisition System Overview\u003c\/h2\u003e\u003cp\u003eThe MAX197BCWI+ is a high-performance 8-channel, 12-bit Data Acquisition System (DAS) from Analog Devices Inc.\/Maxim Integrated, designed for precision measurement and control applications across aerospace, automotive, industrial, medical, and telecommunications sectors. With a 100kSPS sampling rate and parallel data interface, this surface-mount component delivers reliable performance in demanding environments.\u003c\/p\u003e\u003ch3\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8-Channel Multiplexed Input:\u003c\/strong\u003e Efficiently monitor multiple analog signals with a single integrated solution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12-Bit Resolution:\u003c\/strong\u003e Achieve precise measurements with 4096 discrete levels for accurate data conversion\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100kSPS Sampling Rate:\u003c\/strong\u003e Capture fast-changing signals in real-time applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Supply Operation:\u003c\/strong\u003e Simplify power design with 4.75V to 5.25V supply voltage range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface Mount Package:\u003c\/strong\u003e 28-SOIC form factor enables compact PCB layouts and automated assembly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Temperature:\u003c\/strong\u003e Reliable operation from 0°C to 70°C for commercial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliant:\u003c\/strong\u003e Meets environmental standards for global deployment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\u003ccol\u003e\u003c\/colgroup\u003e \u003ctbody\u003e \u003ctr\u003e \t\u003ctd\u003eProduct attributes\u003c\/td\u003e \t\u003ctd\u003eProperty Value\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eManufacturer\u003c\/td\u003e \t\u003ctd\u003eAnalog Devices Inc.\/Maxim Integrated\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eProduct Series\u003c\/td\u003e \t\u003ctd\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003ePackaging\u003c\/td\u003e \t\u003ctd\u003eTube | \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eType\u003c\/td\u003e \t\u003ctd\u003eData Acquisition System (DAS)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eNumber of Channels\u003c\/td\u003e \t\u003ctd\u003e8\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eResolution (Bits)\u003c\/td\u003e \t\u003ctd\u003e12 b\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eSampling Rate (Per Second)\u003c\/td\u003e \t\u003ctd\u003e100k\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eData Interface\u003c\/td\u003e \t\u003ctd\u003eParallel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eVoltage Supply Source\u003c\/td\u003e \t\u003ctd\u003eSingle Supply\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eVoltage - Supply\u003c\/td\u003e \t\u003ctd\u003e4.75V ~ 5.25V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eOperating Temperature\u003c\/td\u003e \t\u003ctd\u003e0°C ~ 70°C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eMounting Type\u003c\/td\u003e \t\u003ctd\u003eSurface Mount\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eGrade\u003c\/td\u003e \t\u003ctd\u003e-\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eQualification\u003c\/td\u003e \t\u003ctd\u003e-\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003ePackage \/ Case\u003c\/td\u003e \t\u003ctd\u003e28-SOIC (0.295\", 7.50mm Width)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \t\u003ctd\u003eSupplier Device Package\u003c\/td\u003e \t\u003ctd\u003e28-SOIC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e   \u003ctd\u003eROHS\u003c\/td\u003e   \u003ctd\u003e\u003cimg class=\"ROSHICON\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0910\/9756\/3425\/files\/ROHSICON.png?v=1757832376\"\u003e\u003c\/td\u003e  \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MAX197BCWI+ is ideal for industrial process control, medical instrumentation, test and measurement equipment, automotive sensor interfaces, and multi-channel data logging systems where precision analog-to-digital conversion is critical.\u003c\/p\u003e\u003ch3\u003eQuality \u0026amp; Traceability\u003c\/h3\u003e\u003cp\u003eAll components at \u003ca href=\"https:\/\/hqickey.com\/\" title=\"HQICKEY - Premium Electronic Components Supplier\"\u003eHQICKEY\u003c\/a\u003e are sourced from authorized distributors with full traceability documentation. We guarantee authentic parts with long lifecycle availability and comprehensive technical support for your design-in requirements.\u003c\/p\u003e\u003ch3\u003eRelated Products \u0026amp; Resources\u003c\/h3\u003e\u003cp\u003eExplore our complete range of \u003ca href=\"https:\/\/hqickey.com\/collections\/adcs-dacs-special-purpose\" title=\"ADCs\/DACs - Special Purpose Components\"\u003eADCs\/DACs - Special Purpose\u003c\/a\u003e components for your precision measurement applications. For the latest industry insights, technical articles, and product updates, visit our \u003ca href=\"https:\/\/hqickey.com\/blogs\/news\" title=\"HQICKEY Technical Blog \u0026amp; News\"\u003eTechnical Blog\u003c\/a\u003e.\u003c\/p\u003e","brand":"Analog Devices Inc.\/Maxim Integrated","offers":[{"title":"Default Title","offer_id":51040827932961,"sku":"MAX197BCWI","price":355904.94,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0910\/9756\/3425\/files\/IC_ADDACSP_175_21-0042_WI_28_ba31c0f8-180a-4348-a9b0-abdcdb57eed5.jpg?v=1742133987","url":"https:\/\/hqickey.com\/products\/max197bcwi","provider":"HQICKEY","version":"1.0","type":"link"}