Skip to product information
1 of 1
Image shown is a representation only. Exact specifications should be obtained from the product data sheet.
Regular price $1.29
Regular price $1.36 Sale price $1.29
Sale Sold out
Quantity Unit Price Total Price
1 $1.29 $1.29
15+ $1.25 $18.75
25+ $1.22 $30.50
50+ $1.16 $58.00
100+ $1.02 $102.00
N+ $0.20 Price Inquiry
Shipping calculated at checkout.
Quantity
Component Recycling

Request Quote / Inquiry

Product attributes Property Value
Manufacturer Power Integrations
Product Series LinkSwitch®-TN2
Packaging Cut Tape (CT) | Tape & Reel (TR)
Output Isolation Non-Isolated
Internal Switch(s) Yes
Voltage - Breakdown 725V
Topology Buck, Buck-Boost, Flyback
Voltage - Start Up -
Voltage - Supply (Vcc/Vdd) 85V ~ 265V
Duty Cycle 69%
Frequency - Switching 66kHz
Power (Watts) -
Fault Protection Current Limiting, Open Loop, Over Load, Over Temperature, Over Voltage, Short Circuit, UVLO
Control Features Frequency Control, Soft Start
Operating Temperature -40°C ~ 150°C (TJ)
Grade -
Qualification -
Mounting Type Surface Mount
Package / Case 8-SOIC (0.154", 3.90mm Width), 7 Leads
Supplier Device Package SO-8C
ROHS RoHS Compliant - Hazardous Substance Free Electronic Components | HQICKEY

The Power Integrations LNK3209D-TL from the LinkSwitch-TN2 series is a non-isolated AC-DC switcher with an integrated 725V breakdown switch. It supports buck, buck-boost, and flyback topologies, operates from an 85V to 265V Vcc supply, and switches at 66kHz with a 69% maximum duty cycle. Frequency control, soft start, and extensive protection including short circuit, open loop, over load, over voltage, over temperature, and UVLO are provided in a 7-lead 8-SOIC package rated for -40°C to 150°C junction temperatures.

  • Integrated 725V breakdown switch reduces external component count in non-isolated designs.
  • Supports buck, buck-boost, and flyback topologies for design flexibility.
  • Extensive protection set (open loop, short circuit, over load, over voltage, over temperature, UVLO) improves reliability.
  • Frequency control and soft start simplify stable operation.
  • -40°C to 150°C junction rating suits demanding thermal environments.

Non-Isolated AC-DC Bias Supplies

The LNK3209D-TL integrates a 725V breakdown switch, making it suited to compact non-isolated buck and buck-boost bias supplies directly from the AC mains.

Appliance and Home Automation Power

With a 66kHz switching frequency and 69% max duty cycle, it supports small non-isolated power stages in appliances and smart-home devices.

Industrial Control Auxiliary Rails

Rated -40°C to 150°C junction temperature, the LinkSwitch-TN2 device fits auxiliary rails in industrial control equipment.

Robust Fault-Tolerant Designs

Comprehensive protection including open loop, short circuit, over load, over voltage, over temperature, and UVLO improves reliability in non-isolated flyback and buck designs.

Q: What topologies does the LNK3209D-TL support?
A: It supports buck, buck-boost, and flyback topologies.
Q: Does it have an integrated switch?
A: Yes, it integrates the power switch with a 725V breakdown rating.
Q: Is it isolated or non-isolated?
A: It is specified as non-isolated.
Q: What is the Vcc supply range?
A: Vcc operates from 85V to 265V.
Q: What switching frequency and duty cycle are supported?
A: 66kHz switching with a 69% maximum duty cycle.
Q: What protections are included?
A: Current limiting, open loop, over load, over temperature, over voltage, short circuit, and UVLO.
Base Product Number : LNK3209D
66kHz 725V 8-SOIC Buck Converter Buck-Boost Converter Flyback Converter Integrated Switch LinkSwitch-TN2 Non-Isolated
Q: What topologies does the LNK3209D-TL support?
A: It supports buck, buck-boost, and flyback topologies.
Q: Does it have an integrated switch?
A: Yes, it integrates the power switch with a 725V breakdown rating.
Q: Is it isolated or non-isolated?
A: It is specified as non-isolated.
Q: What is the Vcc supply range?
A: Vcc operates from 85V to 265V.
Q: What switching frequency and duty cycle are supported?
A: 66kHz switching with a 69% maximum duty cycle.
Q: What protections are included?
A: Current limiting, open loop, over load, over temperature, over voltage, short circuit, and UVLO.