Analog Devices Inc. LTC2378IDE-18#PBF
| Quantity | Unit Price | Total Price |
|---|---|---|
| 1 | $52.37 | $52.37 |
| 15+ | $50.72 | $760.80 |
| 25+ | $49.62 | $1,240.50 |
| 50+ | $46.86 | $2,343.00 |
| 100+ | $41.35 | $4,135.00 |
| N+ | $8.27 | Price Inquiry |
Request Quote / Inquiry
| Product attributes | Property Value |
| Manufacturer | Analog Devices Inc. |
| Product Series | |
| Packaging | Tube | |
| Number of Bits | 18 |
| Sampling Rate (Per Second) | 1M |
| Number of Inputs | 1 |
| Input Type | Differential |
| Data Interface | SPI |
| Configuration | S/H-ADC |
| Ratio - S/H:ADC | 1:1 |
| Number of A/D Converters | 1 |
| Architecture | SAR |
| Reference Type | External |
| Voltage - Supply, Analog | 2.375V ~ 2.625V |
| Voltage - Supply, Digital | 2.375V ~ 2.625V |
| Features | - |
| Operating Temperature | -40°C ~ 85°C |
| Mounting Type | Surface Mount |
| Grade | - |
| Qualification | - |
| Package / Case | 16-WFDFN Exposed Pad |
| Supplier Device Package | 16-DFN (4x3) |
| ROHS |
The LTC2378IDE-18#PBF is an 18-bit, 1M SPS Analog-to-Digital Converter from Analog Devices. This single-channel device features a S/H-ADC architecture and a convenient SPI interface for seamless digital integration. It requires an external reference for operation. The ADC is housed in a compact 16-WFDFN package with an exposed pad for improved thermal performance. It is designed to operate over an industrial temperature range of -40°C to 85°C. This combination of high speed and high resolution makes it an excellent choice for demanding applications in medical, industrial, and scientific fields.
- Industry-Leading Speed: The 1M SPS sampling rate allows for the capture of fast-changing signals, making it suitable for high-frequency applications.
- High Precision: 18-bit resolution ensures extremely accurate digital representation of analog signals, critical for measurement and control systems.
- Compact and Efficient: The 16-WFDFN package with exposed pad saves board space and aids in heat dissipation, enhancing reliability.
- Easy Integration: The standard SPI interface simplifies connection to microcontrollers and DSPs, reducing development time.
High-Speed Data Acquisition
The 1M SPS sampling rate combined with 18-bit resolution makes the LTC2378IDE-18#PBF perfect for high-speed data acquisition systems that require both speed and precision, such as vibration analysis.
Precision Medical Devices
In medical imaging and diagnostic equipment, this ADC's high resolution ensures accurate representation of analog signals, which is critical for reliable diagnoses.
Industrial Automation and Control
With its fast sampling and SPI interface, it can be used in industrial control loops for real-time monitoring of current and voltage, improving system efficiency and safety.
Scientific Instrumentation
The high accuracy and speed make it suitable for spectrometers and other scientific instruments where precise signal digitization is essential for data analysis.
Test and Measurement Equipment
This ADC is ideal for benchtop multimeters and data loggers, providing the necessary resolution and speed to capture transient signals accurately.
Energy and Power Monitoring
In smart grid applications, the LTC2378IDE-18 can be used for high-precision power quality analysis, helping to monitor and manage energy distribution effectively.
- Q: What is the resolution of the LTC2378IDE-18#PBF?
- A: The LTC2378IDE-18#PBF is an 18-bit Analog-to-Digital Converter.
- Q: What is the maximum sampling rate?
- A: It supports a maximum sampling rate of 1M SPS (samples per second).
- Q: How many channels does this ADC have?
- A: It has a single input channel.
- Q: What digital interface does it use?
- A: It utilizes a SPI (Serial Peripheral Interface).
- Q: What is the architecture of the LTC2378IDE-18?
- A: It uses a S/H-ADC (Sample and Hold) architecture.
- Q: What is the package type?
- A: It comes in a 16-WFDFN Exposed Pad package and operates from -40°C to 85°C.
- Q: What is the resolution of the LTC2378IDE-18#PBF?
- A: The LTC2378IDE-18#PBF is an 18-bit Analog-to-Digital Converter.
- Q: What is the maximum sampling rate?
- A: It supports a maximum sampling rate of 1M SPS (samples per second).
- Q: How many channels does this ADC have?
- A: It has a single input channel.
- Q: What digital interface does it use?
- A: It utilizes a SPI (Serial Peripheral Interface).
- Q: What is the architecture of the LTC2378IDE-18?
- A: It uses a S/H-ADC (Sample and Hold) architecture.
- Q: What is the package type?
- A: It comes in a 16-WFDFN Exposed Pad package and operates from -40°C to 85°C.

LTC2378IDE-18#PBF.pdf