Analog Devices Inc. LTC2414CGN#PBF
| Quantity | Unit Price | Total Price |
|---|---|---|
| 1 | $17.49 | $17.49 |
| 15+ | $16.94 | $254.10 |
| 25+ | $16.57 | $414.25 |
| 50+ | $15.65 | $782.50 |
| 100+ | $13.81 | $1,381.00 |
| N+ | $2.76 | Price Inquiry |
Request Quote / Inquiry
| Product attributes | Property Value |
| Manufacturer | Analog Devices Inc. |
| Product Series | microPOWER™ |
| Packaging | Tube | |
| Number of Bits | 24 |
| Sampling Rate (Per Second) | 7.5 |
| Number of Inputs | 4, 8 |
| Input Type | Differential, Single Ended |
| Data Interface | SPI |
| Configuration | MUX-ADC |
| Ratio - S/H:ADC | - |
| Number of A/D Converters | 1 |
| Architecture | Sigma-Delta |
| Reference Type | External |
| Voltage - Supply, Analog | 2.7V ~ 5.5V |
| Voltage - Supply, Digital | 2.7V ~ 5.5V |
| Features | - |
| Operating Temperature | 0°C ~ 70°C |
| Mounting Type | Surface Mount |
| Grade | - |
| Qualification | - |
| Package / Case | 28-SSOP (0.154", 3.90mm Width) |
| Supplier Device Package | 28-SSOP |
| ROHS |
The LTC2414CGN#PBF is a 24-bit, 7.5 SPS analog-to-digital converter from Analog Devices, featuring a multiplexed ADC (MUX-ADC) architecture. It provides 4 or 8 input channels and communicates via an SPI interface. The device requires an external voltage reference for conversion. Packaged in a 28-pin SSOP (0.154", 3.90mm width), it operates over the commercial temperature range of 0°C to +70°C. This ADC is designed for high-precision, low-speed measurement applications such as weigh scales, data loggers, and laboratory instruments.
- Exceptional Resolution: 24-bit conversion delivers high-precision measurement for demanding applications.
- Multi-Channel Input: 4/8 channels allow multiplexed measurement of multiple sensors.
- Low Power Consumption: 7.5 SPS sampling rate minimizes power draw, ideal for battery-operated devices.
- Simple SPI Interface: Easy integration with microcontrollers and digital systems.
- Compact SSOP Package: 28-pin SSOP saves board space in multi-channel designs.
High-Precision Sensor Measurement
The 24-bit resolution and 7.5 SPS sampling rate are ideal for low-speed, high-accuracy measurements of bridge sensors, strain gauges, and pressure transducers.
Data Logging Systems
With 4/8 multiplexed inputs and SPI interface, this ADC can be used in environmental data loggers to record temperature, humidity, and light levels over long periods.
Laboratory Instrumentation
In bench-top multimeters and precision voltage sources, the 24-bit resolution provides the fine measurement steps required for calibration and metrology applications.
Battery-Powered Devices
The low sampling rate and simple SPI interface allow for power-efficient operation in portable battery monitors and energy harvesting systems.
Industrial Weighing
The high resolution and multiplexed inputs enable accurate weight measurement from multiple load cells in industrial scales and filling machines.
Temperature Controller Calibration
In precision temperature controllers, this ADC can digitize thermocouple or RTD signals with high accuracy, supporting tight temperature regulation.
- Q: What is the resolution of the LTC2414CGN#PBF?
- A: It is a 24-bit analog-to-digital converter.
- Q: What is the maximum sampling rate?
- A: The LTC2414CGN#PBF supports a sampling rate of 7.5 SPS.
- Q: How many input channels does it have?
- A: It offers 4 or 8 input channels.
- Q: What interface does it use?
- A: It uses a standard SPI interface.
- Q: What is the ADC architecture?
- A: It uses a multiplexed ADC (MUX-ADC) architecture.
- Q: What is the operating temperature range?
- A: It operates from 0°C to +70°C.
- Q: What is the resolution of the LTC2414CGN#PBF?
- A: It is a 24-bit analog-to-digital converter.
- Q: What is the maximum sampling rate?
- A: The LTC2414CGN#PBF supports a sampling rate of 7.5 SPS.
- Q: How many input channels does it have?
- A: It offers 4 or 8 input channels.
- Q: What interface does it use?
- A: It uses a standard SPI interface.
- Q: What is the ADC architecture?
- A: It uses a multiplexed ADC (MUX-ADC) architecture.
- Q: What is the operating temperature range?
- A: It operates from 0°C to +70°C.